Harrow Mechanical

Capabilities

Capability by system

Mechanical, hydraulic and controls in one riser, commissioned and maintained after handover.

Scroll to see how the three services occupy the same building. Commissioning and maintenance follow below, once the plant is in.

Mechanical, hydraulic and controls in one riser

Riser schematic: mechanical, hydraulic and controls services through a six level buildingA sectional riser diagram. Six levels, L01 at the bottom to L06 at the top, sit above a plant deck. Three service branches rise from the plant deck to level six. The mechanical branch leaves an air handling unit as a supply riser and a return riser, and serves a variable air volume box, a supply diffuser and a return grille on every level. The hydraulic branch leaves a chiller and pump set as a flow riser and a return riser, and serves a fan coil unit with a coil and a fan on every level. The controls branch leaves a building management head end panel as a single trunk, and serves a floor controller, a space sensor and a control line to the fan coil unit on every level.L01L02L03L04L05L06PLANTMECHANICALHYDRAULICCONTROLS

01

Mechanical

Central plant, air handling and distribution for buildings from 2,000 to 40,000 square metres.

  • 01Water and air cooled chiller plant to 2MW
  • 02Air handling units, fan coil units, VAV and CAV systems
  • 03Ductwork fabrication and installation to DW/144
  • 04Kitchen and carpark ventilation to AS 1668.2
  • 05Theatre and cleanroom ventilation with HEPA filtration
  • 06Plant room construction and staged changeover in live buildings

02

Hydraulic

Pressure pipework, reticulation and drainage carrying chilled water, hydronic heating, glycol and trade waste.

  • 01Chilled and condenser water reticulation, DN50 to DN300, welded and pressure tested to AS 4041
  • 02Hydronic heating and low temperature hot water distribution, pre-insulated and vapour sealed
  • 03Glycol reticulation for process and refrigeration duties
  • 04Trade waste, sanitary drainage and roof drainage to AS/NZS 3500
  • 05Pump selection, staging and variable speed control for primary, secondary and tertiary circuits
  • 06Thermal and buffer storage sizing for ride-through and load levelling
  • 07Calorifiers, heated water plant and thermostatic mixing to AS 4032.3

03

Controls

DDC and BMS design, programming and integration, from a single floor extension to a full head end replacement.

  • 01DDC controller design and programming, BACnet/IP and Modbus integration
  • 02BMS head end replacement and points database migration
  • 03Zone control, VAV and VRF sequencing to occupancy and timetable schedules
  • 04Room pressure cascade and containment interlocks to AS/NZS 2243.3
  • 05Fault, alarm and trend logging routed to site engineering or facility management
  • 06Energy metering per floor, per tenancy or per system for NABERS and tenant billing
  • 07Graphics and operator interface built to the existing site standard where one exists